FANCOIL CONTROLLER 3 SPEED

KNX bus device with actuator function (in combination with a KNX room temperature controller) or controller/ actuator (with acquisition of the temperature value by a KNX sensor or by a sensor connected to an analog input). For installations in 2-pipe hydraulic distribution systems with ON / OFF control of an electrothermalactuator on a shut-off valve and a 3-speed fan. The outputs not used for controlling a fan coil unit can be configured as outputs to carry out other functions. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

Power supply from the bus and auxiliary power supply 230 Vac 50/60 Hz , Control of 2-pipe hydraulic distribution systems with shutoff valve ON/OFF (1 SPST relay) , 3 relay outputs to control a 3-speed fan , 2 inputs freely configurable for acquisition of passive temperature sensors (10 kΩ NTC at 25°C) or as potential-free binary inputs

FANCOIL CONTROLLER 0 -10 V

KNX bus device with actuator function (in combination with a KNX room temperature controller) or controller/ actuator (with acquisition of the temperature value by a KNX sensor or by a sensor connected to an analog input). For installations in 2-pipe hydraulic distribution systems with ON / OFF control of an electrothermalactuator on a shut-off valve and 0-10 V control of a fan with brushless motor. The outputs not used for controlling a fan coil unit can be configured as output channels to carry out other applications. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

 Power supply from the bus and auxiliary power supply 230 Vac 50/60 Hz , Control of 2-pipe hydraulic distribution systems with shutoff valve ON/OFF (1 SPST relay) , 1 output 0-10 V for control of a fan with brushless motor , 2 inputs freely configurable for acquisition of passive temperature sensors (10 kΩ NTC at 25°C) or as potential-free binary inputs

FANCOIL CONTROLLER 3 SPEED & 0 -10 V

KNX bus device with actuator function (in combination with a KNX room temperature controller) or controller/ actuator (with acquisition of the temperature value by a KNX sensor or by a sensor connected to an analog input). For installations in 2 or 4-pipe hydraulic distribution systems with ON / OFF control of one or two electrothermal actuators for shut-off valves; control of a 3-speed fan or 0-10 V control of a fan with brushless motor. The outputs not used for controlling a fan coil unit can be configured as output channels to carry out other applications. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

Power supply from the bus and auxiliary power supply 230 Vac 50/60 Hz , Control of 2 or 4-pipe hydraulic distribution systems with shutoff valve ON/OFF (2 SPST relays) , control of a 3-speed fan or 0-10 V control of a fan with brushless motor , 3 inputs freely configurable for acquisition of passive temperature sensors (10 kΩ NTC at 25°C) or as potential-free binary inputs

ACTUATOR/CONTROLLER 8-FOLD FOR ELECTROTHERMAL VALVE DRIVERS

KNX bus device with actuator function (in combination with a KNX room temperature controller) or controller /actuator (with acquisition of the temperature value by a KNX sensor). For 2- and 4-pipe hydraulic distribution systems with 8 TRIAC outputs for ON/OFF control of electrothermal actuators or servomotors for zone valves. Mounting in distribution board on EN 60715 rail (4 modular units, each 18 mm). To be used in KNX installations for home and building automation.

 Power supply from the bus and auxiliary power supply 230 Vac 50/60 Hz
Control of 2- and 4-pipe hydraulic distribution systems 
8 TRIAC outputs for ON/OFF control of electrothermal actuators or servomotors for zone valves

MIXING GROUP CONTROLLER

KNX bus device for the control of a mixing group. Control of a servomotor for mixing valve (3 floating points or with 0-10 V signal). Control of a circulating pump. Acquisition of inflow and return temperatures (conveying fluid) and external temperature (air). Regulation of the inflow temperature of the conveying fluid with regulation modes selectable separately for heating and cooling. Device particularly suitable for underfloor or ceiling heating and cooling radiant panels applications in combination with room thermostats with integrated temperature and humidity sensor. Mounting in distribution board on EN 60715 rail (8 modular units, each 18 mm). To be used in KNX installations for home and building automation.

OUTPUTS
•1 TRIAC output (CLOSE / COM / OPEN) for 3-floating point servomotor (with POWER AUX input for servomotor power supply at 24 Vac or 230 Vac) , 1 output (AO1) for servomotor with 0-10 V control signal , 1 SPST relay output (DO1) for circulating pump control , 2 SPST relay outputs (DO2, DO3) for additional functions

INPUTS
3 analogic inputs (IN1, IN2, IN3) for passive temperature sensors (NTC 10 kΩ at 25 °C) , 2 configurable inputs (IN4, IN5) as analogic (for passive temperature sensors NTC 10 kΩ at 25 °C) or digital (for free-potential contacts)

OTHER CHARACTERISTICS
Power supply from bus and auxiliary 230 Vac 50/60 Hz power supply , Two logic functions with 16 objects each , Overtemperature (heating) and undertemperature (cooling) alarm management  , Alarm management by condensation sensor , Alphanumeric display and membrane keyboard for monitoring of operating parameters and modification of a control parameters subset

TEMPERATURE SENSOR FOR OUTDOOR INSTALATION

Outdoor temperature sensor with NTC sensing element to be used in combination with ekinex® KNX devices equipped with an analog input (or configurable as [AI]) to measure the temperature. The sensing element is protected by a plastic sheath and inserted in a housing with high degree of IP protection; the sensing element is positioned on the bottom of the housing, making this product particularly suitable for detecting the outdoor air mass temperature, for example to realize a compensated regulation or for measuring the outdoor temperature and send it on the KNX bus for information purposes. The housing, with cable gland, includes within it the connecting terminal block; the electrical connection with the ekinex® KNX device is realized by a two-wire cable (not included in delivery).

Sensing element: NTC (10 kΩ ±1% at 25°C, ß = 3435) , Environmental and operating conditions:
- operating temperature: −40°C...+100°C , - relative humidity: 0...100%

TEMPERATURE SENSOR FOR IMMERSION IN PIPING

Immersion temperature sensor with NTC sensing element to be used in combination with ekinex® KNX devices equipped with an analog input (or configurable as [AI]) to measure the temperature. The sensing element is protected by a plastic sheath and inserted in a cylindrical housing in INOX. The probe is suitable for detecting the temperature of the conveying fluid in heating and / or cooling circuits; for the installation it is necessary to provide an immersion sleeve (not included in delivery) suitable for the insertion of the probe into the pipe. The electrical connection with the ekinex® KNX device is realized by the two-wire cable (length 1.5 m).

 Sensing element: NTC (10 kΩ ±1% at 25°C, ß = 3435) , Operating temperature: -40°C...+105°C

TEMPERATURE SENSOR FOR CONTACT MEASURMENT

Contact temperature sensor with NTC sensing element to be used in combination with ekinex® KNX devices equipped with an analog input (or configurable as [AI]) to measure the temperature. The sensing element is inserted into a brass protective sleeve and is suitable for detecting the temperature of the conveying fluid without the need of insertion in the hydraulic circuit; for example by fixing in contact with a pipe or a heat exchange coil of a fancoil unit. The electrical connection with the ekinex® KNX device is realized by the two-wire cable (length 1.5 m).

Sensing element: NTC (10 kΩ ±1% at 25°C, ß = 3435) , Operating temperature: −40°C...+100°C

TEMPERATURE SENSOR FOR AIR MASS MEASURMENT

Temperature sensor for air mass measurement with NTC sensing element to be used in combination with ekinex® KNX devices equipped with an analog input (or configurable as [AI]) to measure the temperature. The version of the sensor is characterized by the sensing element molded directly on the connecting cable; it is particularly suitable for detecting the temperature of the indoor air mass. The electrical connection with the ekinex® KNX device is realized by the two-wire cable (length 1.5 m).

Sensing element: NTC (10 kΩ ±1% at 25°C, ß = 3435) , Operating temperature: −50°C...+105°C (in air)

UNIVERSAL INTERFACE WITH THERMOSTAT FUNCTION

KNX bus device functioning as 4-channel input configurable for the connection of potential-free contacts or passive temperature sensors (NTC 10 kΩ at 25°C, to be ordered separately) and 4-channel output for control of low-consumption LED. Room thermostat function for 4 independent zones. Mounting in wall box or on 35 mm rail (EN 60715) with the support EK-SMG-35 (to be ordered separately). Power supply via bus. Bus terminal block included in the delivery. To be used in KNX installations for home and building automation.

INPUTS (CONFIGURED FOR FREE-POTENTIAL CONTACTS)

ON/OFF switching of single loads or group of loads , dimming of lighting devices , operating of shutters and roller blinds , detecting the state of signaling contacts (from safety devices, alarms, etc.) , recalling and saving of scenes , sending on the bus of values (temperature, brightness, etc.) , switching to forced functioning (lock) , counting of impulses and switching cycles

INPUTS (CONFIGURED FOR NTC 10 kΩ at 25 °C TEMPERATURE SENSORS)
Measurement of room air mass temperature with possibility of sending the value ​​on the bus or using the value for regulation through integrated thermostat function 

OUTPUTS
controlling of low-consumption LED to be used as state feedback, orientation nightlights, etc.

THERMOSTAT FUNCTION
2 points (ON / OFF) or proportional (PWM or continuous) room temperature regulation , Heating and cooling modes with switching via bus  , Operating modes: comfort, standby, economy and building protection with separate setpoints for heating and cooling , Automatic switching of the operating mode depending on presence or opening windows  , Regulation with weighted average between two temperature values